Key Features:
-
AC operating voltage: 90V to 250V ±10%, 50/60Hz
-
No-load power consumption: less than 3W
-
Temperature control range: -50°C to 110°C
-
Temperature measurement accuracy: ±0.5°C
-
Temperature control accuracy: 1°C
-
Temperature display accuracy: 0.1°C
-
Temperature sensor: NTC 10K B3435 ±1%, waterproof
-
Sensor well dimensions (diameter x length): 4 x 25 mm
-
Temperature sensor wire length: 1 meter
-
Maximum allowable load: 10 A (2200 W)
-
Product cutout size: 71 * 28 mm
-
Product size: 75*34*85mm
-
Weight: 162 g
Temperature setting:
Briefly press the "S" button and then use the ᐃ and ᐁ buttons to set the desired temperature. Wait a few seconds and the thermostat will automatically save the value and switch to the mode of maintaining the set temperature. All settings and settings are saved when the power is turned off.
Programming menu:
To enter the programming menu, press and hold the "S" button (about 3 seconds). You will enter the main settings menu.
Press ᐃ or ᐁ to change. Switching modes with the "S" button. Long press "S" or if no button is pressed within 10 seconds, the menu will be stored and exited.
HC (Heating/Cooling) — selection of "Heating" (H) or "Cooling" (C) mode. "Heating" - the heating element, lamps and other heaters are switched by the thermostat. "Cooling" - air conditioner, freezer compressor, fan, etc.
d (delta) — set temperature hysteresis (default 2°C)
LS (Set Low limit) - limiting the lower limit of the temperature range
HS (Set High limit) — limiting the upper limit of the temperature range
PU - delayed start, sets a delay until the next relay operation from 0 to 90 minutes
CA — (Temperature correction) — temperature correction within ±10*С
A7 (AT) - (Timing stop output) - timer operation. The time is set from 0 to 999 minutes. After the time has elapsed, the relay switches off, regardless of the current temperature. This value is not stored in non-volatile memory. If set to 0 - the timer is disabled, normal operation.