Current Clamp HP-870G

For non-contact measurement of alternating current (AC) up to 1000A. Advanced multimeter functions - temperature. Dual display.
Current Clamp HP-870G
Manufacturer: HoldPeak
NOT available.
Expected price: 1 260,00 UAH
from 1 pc : 1 260,00 UAH
from 3 pcs : 1 235,00 UAH ( -2,0%)
from 6 pcs : 1 210,00 UAH ( -4,0%)
Prices are indicated at the time of product availability and may change upon receipt

Current balances:

NOT available

Изображение товара

Product description format_size zoom_out zoom_in

The HP-870G auto-ranging device is designed to measure AC current up to 1000A with a non-contact method. It is also possible to measure voltage in AC and DC circuits, resistance, voltage drop across the p-n junction and temperature. When the circuits are ringing, in addition to the indication, the buzzer signal sounds. The auto-off function helps to conserve battery power. The backlight of the display allows you to use the clamp meter in low-light places. The measured parameters can be held on the display using the "HOLD" button.

Characteristics:

Function Range Accuracy Resolution Remarks
DCV 200mV ±1.0%of rdg 0.1mV Overload protection: 1000 V DC or AC RMS
Input impedance:10MΩ(200Mv more than 100MΩ)
2V ±1.0% of rdg 1mV
20V ±1.0% of rdg 10mV
200V ±1.0% of rdg 100mV
1000V ±1.0% of rdg 1V
ACV 200mV ±2.0% of rdg 0.1mV Overload protection: 750 v DC or AC RMS /200mVUSE RANGE / Input impedance:10MΩ/ Measurement frequency range:2V~200V: 40~400Hz, 750V: 40~100Hz/ Display: average response (with sinusoidal RMS calibration)
2V ±1.0% of rdg 1mV
20V ±1.0% of rdg 10mV
200V ±1.0% of rdg 100mV
750V ±1.5% of rdg 1V
ACA 2A ±4.0% of rdg 1mA Overload protection:600Arms,(60 sec. Measurement frequency range:50~60Hz
Display: average response (with sinusoidal RMS calibration)
20A ±2.5% of rdg 10mA
200A ±2.5% of rdg 0.1A
0-800A ±3.0% of rdg 1A
800-1000A ±4.0% of rdg 1A
Ω 200Ω ±1.0% of rdg 0.1Ω Overload protection: 250 V DC or AC RMS
2KΩ ±1.0% of rdg
20KΩ ±1.0% of rdg 10Ω
200KΩ ±1.0% of rdg 100Ω
2MΩ ±1.0% of rdg 1KΩ
20MΩ ±2.0% of rdg 10KΩ
Diode Test Range Description Test Condition Overload protection: 250 V DC or AC RMS
  Display value is measured diode and triode p-n junction positive pressure drop approximation forward DC current: approximate 1mA 
Reversed DC voltage: approximate 1.5V
Continuity   Built-in buzzer will sound if resistance is lover than 70Ω Open circuit voltageapprox.0.4V Overload protection: 250 V DC or AC RMS
Temperature
(℉/℃)
Range Accuracy Resolution Overload protection: 36 V DC or AC RMS
-20~300℃ ±3℃+2 1℃
-20~300℃ ±3.0%of rdg 1℃


Maximum display readings - 1999
Instrument power supply - 9V, 1 element type "crown" (6F22)
Overall dimensions - 225x97x40mm
Weight - 0.45kg

Leave your feedback or ask a question

Only this product is discussed here. Off topic comments will be deleted! Please follow the Commenting Rules.

The data presented in the product description are for reference only and may differ from those indicated by the manufacturer.
To carry out technical calculations and obtain the exact parameters of the goods, use the datasheets from the manufacturer's website.

If you need additional information, or you found an error in the description, or have other questions about this product, then our manager will help you: Ярослав unknown