One-component high temperature flame retardant sealant is applied in industrial boilers, industrial electrode furnaces, for repairing and filling high temperature places such as fireplaces, stoves, chimneys, high temperature pipelines, ovens, bakeries, etc. Bonding, sealing and repairing high temperature equipment, fireproofing engineering tunnels, Bonding and sealing industrial products such as pipes for engineering and industrial equipment.
Features:
Viscosity (at 25°C): 8000 ~ 12000
Relative density (g/cm3, 25 ℃): 1.65
Surface Drying Time (min, 25 ℃): 5 ~ 15
Full cure time (days, 25 ℃): 3 ~ 7
Hardness (Shore A): 95
Tensile Strength (MPa): 1
Peel strength (N/mm): 6
Shear strength (MPa): ≥ 1.2
Working temperature range (℃): -60 ℃ ~+1300 ℃
Volume resistance (Ohm • cm): ~ 3.0 × 10
15
Dielectric strength (kV/mm): ≥20
Dielectric constant (1.2 MHz): 3.88
Application rules:
1. Clean surfaces, remove rust, dust, oil.
2. Cut off the nozzle cap, install the cut off the tip
Use a glue gun to apply the sealant evenly.
Press down the surfaces to be glued.
3. Let it dry naturally at room temperature for 30 ~ 60 minutes
Then heat the bonding area to 80 ~ 120 ℃
2 hours, wait for the bonded area to cool slowly, and leave at room
temperature for 8 ~ 24 hours.
full cure time is usually 3 ~ 7 days (at 25 ℃)
A lower temperature will also extend the cure time.
4. Recommendation: Do not move or use until the sealant is completely dry.
Store in a cool and dry place and make sure it is out of reach of children. After completion of the operation, unused adhesive should be sealed immediately.
This product is mildly irritating to the skin and eyes, if it accidentally comes into contact with the skin, wipe with a clean cloth, then rinse with water, if accidentally splashed into the eyes, use a clean cloth and rinse with water and consult a doctor for examination.